See inside your critical infrastructure.

Xintrax reads the equipment you already have (UPS, switchgear, cooling, fire panels, access control) and turns it into one live picture of your site. Read-only by design. It runs on site, even without internet.

Live one-line diagram of a data center power path Utility, transformer, switchboard, UPS and two power panels feeding IT racks, with live readings. The UPS room temperature rises above its limit and Xintrax highlights it. Power path Utility480 V service XFMR-1500 kVA SWBD-IT312 kW UPS-1196 kW Room81.0 °F RPP-A98 kW RPP-B97 kW IT racksA + B feeds Around it Fire panelNormal, read-only Access controlDoors closed CRAH-1 supply68.4 °F
Live, read-only: every value above is read from the equipment, nothing is ever written back.

Your facility already has the data. Xintrax reads it.

No new sensors and no changes to your equipment. Xintrax connects to what is installed today, checks every reading against the real equipment, and shows power, cooling and safety systems in one place.

  • PowerUPS, switchgear, transformers, power panels and meters
  • CoolingCRAH, CRAC, in-row cooling, chillers and room sensors
  • Life safetyFire alarm and clean agent panels, EPO, leak detection: monitored only, never commanded
  • AccessDoor states and the access log from your access control system
  • ProtocolsModbus TCP, SNMP v2c/v3 and BACnet/IP, read-only
  • Alarms that explain themselves

    Limits per point, alarms that clear on their own, and a timeline of what happened first.

  • Capacity and redundancy

    How much load each path carries and what happens if its pair fails.

  • Outage survival

    UPS runtime, generator fuel and autonomy, and the cooling that depends on them.

  • Energy and PUE

    Real-time PUE from your own meters, with history you can export.

  • Commissioning and acceptance

    Every point verified in the field with evidence; acceptance tests recorded.

  • Xin, the advisory assistant

    Suggests where to look and why. It cannot act on equipment or override anyone.

From installation to operation in days, not months

  1. Install the edge on site

    A laptop or mini PC on your facility network. One command; it keeps working without internet.

  2. Connect read-only

    Modbus, SNMP and BACnet, reading only. Nothing is ever written to your equipment.

  3. Verify every point

    Each reading is checked against the real equipment and recorded with evidence.

  4. Operate

    Alarms, trends and capacity in one view. Connect more sites to Xintrax Central when you are ready.

Built for places that cannot fail

Security is part of the product, not a setting. These protections are on in every installation.

Read-only by design
The protocol clients cannot send write commands. Life-safety systems and the critical power path are never commanded.
Signed software and licences
Every update and licence is signed and verified on site, offline. A failed update rolls back automatically.
Access you can audit
Multi-factor sign-in, roles per site and an append-only audit log of every sign-in, change and export.
Hardened site equipment
Encrypted disk, closed firewall, USB devices blocked unless approved, and an alarm when someone tries.
Standards
Engineered in line with IEC 62443 and NIST SP 800-82, and ready for FIPS 140-3 environments.
Your data stays yours
Data lives on your site. Sending it to Xintrax Central is your decision and is signed end to end.

Our threat model and security baseline are available to customers under NDA. Alignment with a standard is not a certification.

Made for critical facilities

Data centers

Colocation, enterprise and edge sites: power chain, cooling, capacity and PUE, from commissioning to daily operation.

Hospitals

Power, cooling and medical gas monitoring with NFPA 99 limits, without touching clinical systems.

Government

Offline operation, signed software, FIPS-ready builds and a documented security posture.

Packages

Annual licence per installation. Monitoring and alarms are always included and never switched off.

Feature EssentialsConnect and monitor ProfessionalCommission and operate EnterpriseMany sites, one view
Live monitoring, alarms, auditIncludedIncludedIncluded
Equipment connections and site setupIncludedIncludedIncluded
Point verification and acceptance testsNoIncludedIncluded
Outage survival, energy and PUE, capacityNoIncludedIncluded
Xintrax Central (multi-site)NoNoIncluded
Xin advisory assistantNoNoIncluded

Add-ons for any package: medical gas monitoring, physical access log, and supervised control of non-safety equipment (only on request, with two-person approval).